SHOT BLASTING SYSTEM

A component carried with the help of Gantry and placed on trolley and then it will enter to Shot blasting area.

  • Shot Blasting Enclosure – with Cartridge Type Recovery System - Technical Specifications
  • Blast Room Enclosures
    • MS wall Construction.
    • Size – 8 x 5 x 4.5 – LWH, M
  • Bucket Elevator & Media Separator
  • Main Door-Hinge Type with Air Louvers
  • Dust Collector Cartridge System
  • Single Screw Media Recovery System

PAINTING BOOTH – DOWN DRAFT TYPE – DRY TYPE

  • Non Pressurized Dry type Down Draft Spray Booth.
  • Here also component carried with the help of Gantry and placed on the trolley and then it will enter to painting area.
  • Entry exit door (Common) – Manual operated sliding door.
  • Floor is covered with metal grating over exhaust pit.
  • Paint arrestor filters are provided in the length wise civil pits at the bottom.

Technical Specification:

Booth Encloser Booth
Length (M) 8
Clear Width (M) 5
Clear Height (M) 4.5
Air Down Draft (m/s) 0.50
Exhaust Blower (m cub/H) 2 X 36000
Illumination (Lux) 800

Powder Coating Booth

Back to back MS shell powder coating booth with Multi-cyclone recovery.

Technical Specification:

Sr No Specification Unit Powder Coating Booth
A Type of Booth - Closed Enclose with Cylone Recovery
B Working Dimensions M 5 X 1.2 X 2.3, LWH
C Blowers
Capacity of Blower M 3/Hr 1 X 4000
D Mono Cyclone
Mono Cyclone of Each Set No. 1.0
No. of Sets of Mono Cyclone No. 1.0
Capacity of Blower M 3/Hr 1 X 4000
E Cartridge Filters
No. of Cartridge on each set - 4
No. of sets of Cartridge - 1
Capacity of Each Cartridge M3/Hr 1000
F Illumination
Tube Light 2 X 40W Nos 4.0
Lighting Fixture Dust Free, Hindge
Florescent Tube Non Flame Proof
Mounting On Structural Frame
G Painting for MS Surface - Inside Two coat of Epoxy
- Outer-Surface Primer + Synthetic Enamel White Paint

POWDER CURING/PAINT DRYING OVEN-BATCH TYPE

  • Ground Mounted Oven
  • Direct Gas Fired heating
  • Considered common oven for Powder Curing and Paint drying with selector switch option
  • Provided safeties like high temperature controller, air pressure switch in addition to interlock between blower & burner.
  • LPG Gas Leak detector provided at all the gas trains with burner.
  • Provided with three different programs on PLC for various curing operation.
  • Provided with three different programs on PLC for various curing operation. Conventional entry and exit.

Technical Specification:

Sr No Description Unit Oven
1 Track Time Min 30.0
2 Panel Moc -- GI
3 Panel Thickness Mm 1.25
4 Insulation Thickness Mm 200
5 Heating System -- Direct Gas Fires
6 Moc Combution Chamber -- SS 304 3 thk
7 Heating Meduim LPG
8 Length Oven M 7.4
9 Air Temp C 220
10 Total Active Time - 30.0
11 Oven Heat-up Time Max (from cold state) min 20.0
12 Over Width M 4.1
13 Oven Heat 3.75
Heat Up Zone
14 Initial Heat Load Kcal/hr 1,86,000
15 Running Heat Load Kcal/hr 1,17,000
16 Burner Capacity Kcal/hr 2,00,000
17 Circulation Blower Capacity M3/hr 30,500
18 No of Units Nos. 1.0